Similar Posts
2x 12V DC circuits in one cable possible?
Hello, following facts: 1 Unitronic bus cable, including: 3x2x0.25mm² and 3×1.0mm² Colors 1.0mm²: Red, Blue, Green/Yellow Colors 0.25mm² (twisted pair): Brown + Brown/White, Green + Yellow, Pink + Grey Two separate “devices” are now operated via the cable. These are powered by two different power supplies: one with 11.5V DC and the other with 12.7V…
PC monitor no signal?
I registered my PC and then the I used HDMI as usual the PC uses Windows XP as usual what is the reason for this
How do I connect a second monitor?
So, of course, I know how to connect it, but how do I set it up correctly? I want to play Elden Ring on one monitor and collect stats and other things on the other. How can I do that at the same time? When I tried it, either the same thing happened on both…
How do you bleed a completely painted heater?
I live in an older apartment building, and almost all of the radiators in this apartment are completely painted. This means there are no vent valves, or rather, the vent valves are completely painted. How do you bleed these radiators?
Broken faucet – how to repair?
In our case, the inner support of a faucet has probably broken; the faucet wobbles and is movable. Does anyone know what exactly is broken/defective? It would have to be internal components. Thanks!
How do I clean the lint filter in my washing machine?
ByFio108
I took out the lint filter from the washing machine and cleaned it under running water, but it still smells musty. What can I do or how can I get rid of the smell?
Cable fires caused by unqualified personnel.
It has been determined which performance should be provided. If you don’t stick to the parameters, you might end up dying.
The line average and the insulation determine the maximum current and the maximum voltage. There is a TGL.
Anyone who intentionally connects more consumers to a place of acceptance than is provided. He’s a perpetrator with full liability.
And how to avoid that? Work protection and education. Unauthorised not to switch off technical installations or electricity!
If power lines are overloaded
Inadmissible heating.
By avoiding overloading of a line.
How can this be implemented in practical terms? Can’t you burn long light in winter or do you already have a small outlet light for a fire? My apartment (or the house) was built in 2000, so no old building.
Since each line is secured in accordance with its permissible load capacity. This is guaranteed in every house, unless someone else has walked around the electrical system.
It doesn’t change.
Correction: My house was built not in 2000, but in 2020.